Miami, FL Site Plans: Three Stacked Rulebooks—Miami 21, HVHZ Wind Loads, and Coastal Flood Levels
Create My Miami Site Plan Now → Get a Done-For-You Plan →
Does the City of Miami Require a Site Plan—And Can You Draw Your Own?
Yes, nearly every permitted project requires a site plan—and for most structural projects beyond simple fences, Miami requires drawings sealed by a Florida-licensed professional.
We give you the straight answer up front so you don't waste time: the City of Miami combines three of the strictest permitting rulebooks in the country—Miami 21 transect zoning, High-Velocity Hurricane Zone (HVHZ) structural wind standards, and coastal flood elevation mandates. Because of that complexity, City of Miami and Miami-Dade County typically require sealed plans prepared by a Florida-licensed architect, engineer, or surveyor for additions, pools, ADUs, and commercial construction.
Where a browser-based creator helps immediately is before you hire a licensed professional: confirming your Miami-Dade parcel lines, testing Miami 21 transect setback math (T3 through T6), checking lot coverage limits, mapping 18-inch trees, and visualizing simple fence layouts before committing to expensive architectural fees.
First, double-check jurisdiction: Miami-Dade County contains 34 incorporated municipalities plus unincorporated county zones. Only properties inside City of Miami city limits submit through Miami's iBuild / ProjectDox (ePlan) system—while unincorporated Miami-Dade parcels route to the Herbert S. Saffir Permitting and Inspection Center (11805 SW 26th St.), and neighboring cities like Miami Beach, Coral Gables, and Hialeah operate their own portals.
Who Uses Preliminary Parcel Planning in Miami
- Homeowners mapping backyard fences (permitted under Section 33-11), pools, sheds, decks, patios, ADUs, and additions in Coconut Grove, Little Havana, Brickell-adjacent corridors, and Morningside to verify T3 transect room before calling a Florida engineer.
- Contractors estimating fence, driveway, garage, and exterior concrete scopes across Miami neighborhoods who need exact parcel folio numbers and setback previews before quoting jobs.
- Builders screening T4 and T5 urban infill lots against Floor Lot Ratio (FLR), build-to lines, and January 2025 Administrative Site Plan Review (ASPR) thresholds prior to full civil engineering.
- Commercial real estate teams preparing preliminary site studies for retail/mixed-use renovations and parking allocations under Miami 21 Article 4, Table 4.
- Manufactured home retailers, manufactured home dealers, modular home retailers, modular home dealers, mobile home retailers, and mobile home dealers confirming HVHZ wind-zone compliance, flood elevations, and municipal zoning restrictions before proposing factory-built placements in Miami-Dade County.
Layer 1: Miami 21 Transect Setbacks & Coverage Caps
Under Miami 21, setbacks and maximum lot coverage follow your property's specific transect zone rather than a uniform suburban standard:
| Transect Zone | Typical Context | Front Setback | Side Setback | Rear Setback | Max Lot Coverage |
|---|---|---|---|---|---|
| T3 (Sub-Urban) | Single-family residential | 20 ft | 10 ft (7.5 ft on lots <50 ft wide) | 20 ft | 50% |
| T3-R (Sub-Urban Restricted) | Single-family restricted | 20 ft | 5 ft minimum | 20 ft | 50% |
| T4 (General Urban) | Mixed residential/neighborhood | 10 ft | 5 ft | 20 ft | 60% |
| T5 (Urban Center) | Higher-density mixed-use | 0–10 ft (build-to line) | 0 ft | 10 ft | 80% |
| T6 (Urban Core) | Downtown & urban core | 0 ft (build-to line) | 0 ft | 10 ft | 80% |
Look up your exact parcel zone on the Miami 21 Zoning Atlas before locking in any footprint—using T3-R side setbacks on a standard T3 parcel will trigger first-round plan rejection.
Layer 2 & Layer 3: HVHZ Wind Ratings + Coastal Flood Elevations
HVHZ Applies Even to Fences & Sheds
Only two counties in the United States carry the High-Velocity Hurricane Zone (HVHZ) designation: Miami-Dade and Broward County. That means backyard permits carry strict engineering and product rules:
- 170–180+ mph design wind speeds under ASCE 7-22, Risk Category II.
- Miami-Dade NOA (Notice of Acceptance) product approvals required on exterior components, impact glazing/approved shutters (plywood does not qualify), roofing, and fencing.
- Explicit wind-speed notation printed right on the site plan itself.
Flood Zone & Elevation Data on Every Plan
Because coastal elevation governs drainage and foundation height across Miami regardless of distance from Biscayne Bay, every site plan must include:
- Flood zone designation and FEMA panel number
- Base Flood Elevation (BFE)
- Finished Floor Elevation (FFE) measured relative to both BFE and Crown of Road
Projects Triggering Site Plans & Seals in Miami
| Project Type | Key City of Miami Rule | Items Required on Your Site Plan |
|---|---|---|
| Fence or Wall | All walls and fences require permits (Section 33-11) | Fence path, gates, height, setbacks, HVHZ wind compliance & NOA specs. |
| Pool | Setbacks measured from water's edge, not deck edge | 48" min barrier fence per FL Statute 515.29, gate latch, HVHZ-rated equipment pad. |
| Shed or Garage | Permit + HVHZ wind-load anchoring required | Footprint, setbacks, distance from main dwelling, NOA/wind notation, 18"+ tree survey. |
| Deck or Patio | Covered/structural decks require sealed plans & coverage math | Footprint, attachment, lot coverage %, impervious area, BFE/FFE context. |
| Addition or ADU | Sealed architectural/engineering plans + Miami 21 FLR check | Existing & new footprints, Floor Lot Ratio (FLR), parking per Article 4 Table 4, tree survey. |
| Driveway | Right-of-way permit checks apply | Public ROW boundaries, curb cut width, apron geometry, swale drainage. |
Inside ProjectDox (ePlan) Prescreen & January 2025 ASPR Rules
Don't Get Bounced by File Formatting in iBuild & ProjectDox
The City of Miami takes applications in iBuild and reviews drawings inside ProjectDox (ePlan). Formatting mistakes bounce files at prescreen before a reviewer reads a single note:
- Submit unencrypted PDF files only (no password protection), max 1 GB per file.
- Use ALL UPPERCASE filenames with dashes allowed—zero spaces or special characters.
- Format drawings in landscape orientation and leave the upper-right corner of every sheet completely blank for the city approval stamp.
- Upload each drawing page as its own separate file (ten pages = ten separate PDFs).
Administrative Site Plan Review (ASPR — Introduced January 2025)
Under Miami's January 2025 Administrative Site Plan Review (ASPR) process, zoning-compliant projects can lock in formal administrative approval and 3-year vesting protection against future zoning shifts (up from 2 years for Special Permits including Exceptions, Warrants, Waivers, and ASPRs) before paying for full construction engineering. Application fees run \$200 plus \$0.05 per square foot (\$1,000 minimum), with an added \$495 re-review fee beyond three review cycles.
How to Build Your Preliminary Miami Layout in 5 Steps
- Enter your Miami address. Pull confirmed Miami-Dade County parcel boundaries automatically from county GIS records and record your 13-digit Miami-Dade Folio Number in the title block.
- Generate setbacks for your exact Miami 21 transect. Look up T3, T3-R, T4, T5, or T6 on the Miami 21 Atlas and display accurate front, side, and rear clearances.
- Place tree markers for trunks 18 inches or larger. Miami checks tree surveys for every tree 18 inches or greater in diameter—mark trunks early so footprints avoid protected canopy conflicts.
- Edit your title sheet. Populate your 13-digit Folio Number, wind-speed placeholder, BFE/FFE fields, and keep the upper-right sheet area clean.
- Follow the complete walkthrough and hand off to licensed pros. Export the landscape preliminary PDF for early fence planning or hand the organized base map straight to your Florida-licensed architect, engineer, or surveyor for sealed iBuild/ProjectDox submission.
Where This Tool Fits — and Where It Doesn't
| Best Uses in Miami | When Florida-Licensed Pros Are Mandatory |
|---|---|
| Early-stage transect setback checks, T3–T6 coverage screening, and 18" tree mapping | Florida-licensed architect, engineer, or surveyor seals required for additions, pools, ADUs, decks, and commercial projects |
| Simple fence layouts alongside Miami-Dade standard wind-load fence details (Section 33-11) | FEMA Elevation Certificates, BFE/FFE survey certifications, and NOA engineering |
| Aligning property owners and contractors on scope before spending on ASPR engineering | Formal Administrative Site Plan Review (ASPR) and ProjectDox sealed submissions |
What This Doesn't Replace
SitePlans.ai produces preliminary, conceptual, permit-style site plans for planning, estimating, and early layout prep. It is not a legal boundary survey, a Florida-licensed engineer's, architect's, or surveyor's seal, a FEMA Elevation Certificate, Miami-Dade NOA structural engineering, or a guarantee of permit approval. The City of Miami and Miami-Dade County typically require plans sealed by a Florida-licensed professional for most projects beyond basic fences—engaging a licensed professional remains mandatory wherever sealed plans, Elevation Certificates, or ASPR filings apply.
Comparing Your Miami Planning Options
| Method | Time to Build | Uses Miami-Dade County GIS? | Includes FL Professional Seal? | Cost |
|---|---|---|---|---|
| Hand Sketch | 2–5 hours | Manual tracing | No (and fails ePlan formatting) | Free |
| Florida Architect / PE / PLS | 4–10 weeks | Yes (field-surveyed) | Yes (required for most Miami builds) | \$1,800–\$7,500+ |
| SitePlans.ai (Preliminary) | 10 minutes | Yes — confirmed live | No (preliminary planning layout) | First plan free (\$0 to start) |
| SitePlans.us (Done-For-You) | Fast turnaround | Yes | Human-reviewed, non-certified plan | Flat per-project pricing |
Common Mistakes That Bounce Miami Submittals
- Wrong ProjectDox filenames: Including spaces, lowercase letters, or special characters causes immediate prescreen rejection.
- Applying T3-R setbacks to a T3 parcel (or confusing City of Miami with Miami-Dade): Confirm exact transect zone and municipal limits first.
- Leaving out BFE, FFE, Crown of Road, or the 13-digit Folio Number: All four belong on Miami site plan sheets.
- Skipping HVHZ wind notation or the 18-inch tree survey: Even small accessory permits face wind and tree compliance checks.
Local Resources & Official Links
- City of Miami Building Department — Municipal building permit guidelines, fee schedules, and ASPR details.
- Miami 21 Zoning Atlas — Look up your parcel's exact T3–T6 transect zone and overlay codes.
- City of Miami Digital Permitting (iBuild & ProjectDox) — File naming rules, upper-right stamp margin instructions, and upload portals.
- Miami-Dade Property Appraiser — Look up your mandatory 13-digit Folio Number and recorded ownership details.
Nearby Florida Cities & Counties
- Miami-Dade County, FL — Permitting rules for unincorporated Miami-Dade via the Herbert S. Saffir Center.
- Fort Lauderdale, FL — Neighboring Broward County HVHZ wind standards and coastal permitting.
- West Palm Beach, FL — Palm Beach County residential site plan guidelines.
- Fort Myers, FL — Southwest Florida flood elevation and site plan requirements.
- Florida State Permit Guide — Statewide building code rules, Statute 515.29 pool barriers, and county coverage overview.
Pricing
Your first plan is free — no card required. Pull your Miami-Dade folio parcel right now to verify transect setbacks before engaging a licensed architect or engineer.
| Plan | Price | Best For | What You Get |
|---|---|---|---|
| Free / Basic | \$0 | Homeowners testing one Miami lot | One project, 5 PDF exports, landscape title sheet, editable title block, property lines |
| Contractor Pro | \$69/mo | Fence, pool & remodeling contractors in South Florida | Repeat client projects, branded title blocks, advanced layer controls |
| Builder Plan | \$299/mo | Builders & developers | Multiple sheet sizes, company branding, advanced layers |
| Done-For-You | From SitePlans.us | Complex non-certified drafts or urgent prep | Human-reviewed, non-certified permit-style site plan |
For Enterprise deals contact sales@siteplans.ai
Frequently Asked Questions
1. Can homeowners draw and submit their own site plan in the City of Miami?
For early feasibility checks and simple fences pairing with Miami-Dade pre-approved standard wind details, preliminary layouts work well—however, for additions, pools, ADUs, decks, and commercial work, the City of Miami typically requires plans sealed by a Florida-licensed architect, engineer, or surveyor.
2. How does Miami 21 change my setback numbers?
Miami 21 regulates placement by transect zone rather than uniform suburban standards. For example, T3 allows 20 ft front / 10 ft side (7.5 ft under 50 ft width) / 20 ft rear with 50% coverage, T3-R drops side yards to 5 ft, and T5/T6 move frontages to build-to lines with up to 80% coverage. Always confirm your transect on the Miami 21 Zoning Atlas.
3. Does HVHZ (High-Velocity Hurricane Zone) apply to residential fences and sheds?
Yes. Both Miami-Dade and Broward counties enforce HVHZ wind standards (170–180+ mph, ASCE 7-22 Risk Category II, and NOA product approvals) across structural sheds, fences, impact openings, and exterior equipment pads, and require wind compliance notation on your plan.
4. What flood details must appear on every Miami site plan?
Include your FEMA flood zone designation, FEMA panel number, Base Flood Elevation (BFE), and Finished Floor Elevation (FFE) measured relative to both BFE and Crown of Road.
5. How are pool setbacks and barriers regulated in Miami?
Pool setbacks measure from the water's edge rather than the deck edge. Under Florida Statute 515.29, every pool requires a minimum 48-inch safety barrier, compliant gate latches, and HVHZ-rated equipment pads shown on the site plan.
6. What file formatting errors bounce plans in ProjectDox (ePlan)?
ProjectDox prescreen rejects encrypted PDFs, files containing spaces or lowercase letters (use ALL UPPERCASE with dashes only), portrait layouts, multi-page combined PDFs (upload one sheet per file), or drawings lacking a blank upper-right stamp box.
7. What is Administrative Site Plan Review (ASPR)?
Introduced in January 2025, ASPR allows zoning-compliant projects to gain administrative site plan approval and 3-year zoning vesting protection (\$200 + \$0.05/sq ft application fee, \$1,000 minimum) before commissioning full construction engineering.
8. What is a 13-digit Folio Number and where do I find it?
It is Miami-Dade County's unique parcel tax identifier, required on City of Miami applications and lookable via the Miami-Dade Property Appraiser.
9. When is a tree survey required in Miami?
City of Miami submittals require identifying every tree measuring 18 inches or larger in diameter on the site layout.
10. Does SitePlans.ai automatically pull parcel geometry in Miami?
Yes. Miami-Dade County parcel coverage is live inside SitePlans.ai so lot boundaries populate automatically—keeping in mind that final formal permits generally still require Florida-licensed seals and FEMA Elevation Certificates.
Preview Your Miami 21 Setbacks Before Paying for Sealed Prints
Pull your Miami-Dade Folio boundary in seconds, verify T3–T6 setbacks and lot coverage math, and organize your preliminary layout cleanly.
Need a human specialist to assemble a clean non-certified preliminary layout first?
